Medical Device Certification


⚫ What are Medical Devices?

Tools, machines, devices, materials, or similar products used on humans or animals, either alone or in combination, that fall under any of the following subparagraphs

  1. Products used for the purpose of diagnosing, treating, alleviating, managing, or preventing disease
  2. Products used for the purpose of diagnosing, treating, alleviating, or correcting injury or disability
  3. Products used for the purpose of inspecting, replacing, or modifying their structure or function
  4. Products used to control pregnancy

🌐 Country-specific classification and basic information

Medical devices are classified into classes based on the degree of potential risk to the human body.

🇰🇷 KOREA (MFDS)

  • Classification
ClassRiskExample
Class 1Very Low risk• Medical compression stockings
• Manual wheelchair
• Medical gloves
• Dental implant instruments


Medical gloves
Class 2Low risk• Electric wheelchair
• Digital thermometer
• Hearing aid
• Personal combination stimulator


Hearing aid
Class 3High risk• Artificial Joints (Hip/Knee)
• Hemodialysis Machine
• Automated External Defibrillator (AED)
• Artificial Heart Valve
Class 4Very High risk• Pacemaker
• Implantable drug infusion device
• Artificial cardiopulmonary device
• Stent (for cardiovascular)
  • Basic Information
    • Test Standards: ISO, IEC
    • Certification Body: Private certification body designated by the Ministry of Food and Drug Safety
    • Testing Institution: Testing institution designated by the Ministry of Food and Drug Safety
    • Main procedures
      • Product safety review
      • QMS-KGMP

🇺🇸 USA (FDA)

  • Classification
ClassRiskExample
Class ILow risk• Manual Wheelchair
• Medical Gloves
• Elastic Bandages
• Scalpels
• Dental Floss


Manual Wheelchair
Class IIIntermediate risk• Blood Glucose Monitor
• Powered Wheelchair
• Condoms
• Ultrasound Diagnostic Devices
• Infusion Pumps


Powered Wheelchair
Class IIIHigh risk• Pacemaker
• Heart Valves
• Breast Implants
• Ventricular Assist Devices
• High-risk IVD


Pacemaker
  • Basic Information
    • Test standards: ISO, IEC, 21 CFR
    • Certification Body: CDRH under the FDA
    • Testing Institution: No specific testing period is designated; reports from suitable laboratories or inspection bodies (capable of conducting tests against ISO or IEC standards) are accepted.
    • Main procedures
      • Product safety review

🇪🇺 EUROPE(CE)

  • Classification
ClassExample
Class I• Manual wheelchair
• Vision correction glasses
• Disposable Masks


Disposable Masks
Class I m (measuring function)• Clinical Thermometer (Passive)
• Blood pressure monitor (Passive)
• Blood glucose meter


Clinical Thermometer (Passive)
Class I s (sterile condition)• Sterile syringes
• Sterile gauze and bandages
• Sterile surgical supplies


Sterile syringes
Class I r (reusable surgical)• Forceps & Clamps
• Surgical Scissors
• Retractors


Retractors
Class IIa• Clinical Thermometer (Active)
• Dental Fillings
• Hearing aids


Clinical Thermometer (Active)
Class IIb• Ventilator
• Hemodialysis machine
• Surgical Laser Devices


Ventilator
Class III• Heart valves
• Hip prosthesis
• Implantable Drug Injector


Hip prosthesis
  • Basic Information
    • Test Standards: Harmonised European Standards
    • Certification Body: Check List of Notified Bodies (NBs)
    • Testing Body: Testing conducted by a Notified Body (NB).
    • Main procedures
      • Product safety review
      • QMS-ISO 13485

🇨🇳 CHINA (NMPA)

  • Classification
ClassRiskExample
Class ILow risk• Manual Surgical Instruments: Surgical scissors, Forceps, Scalpel handles

• Examination Device: Medical examination chairs, Surgical lights, Stethoscopes

• Physical Therapy Equipment: Medical hot packs, Manual wheelchairs, Orthopedic splints
Close-up of a classic stethoscope on a blue background, symbolizing healthcare and medical profession.

Stethoscopes
Class IIMedium risk• Electronic Diagnostic Equipment: Electronic blood pressure monitors, Digital thermometers, ECG monitors, Ultrasound imaging systems

• Aesthetic & Medical Laser Devices: Medical laser therapeutic devices, Intense Pulsed Light (IPL) equipment

• Surgical & Ward Supplies: Disposable surgical masks & gowns, Disposable syringes, Medical sterilizers

• Dental Materials: Dental impression materials, Dental implant surgical instruments, Dental dental units
A digital sphygmomanometer on a white background, used for measuring blood pressure.

Electronic blood pressure monitors
Class IIIHigh risk• Implantable Medical Devices: Cardiac pacemakers, Artificial joints, Vascular stents

• Injectable Biomaterial: Dermal fillers (Injectable sodium hyaluronate gel)

• Life Support Systems: Mechanical ventilators, Anesthesia machines, Hemodialysis equipment
Close-up of a woman receiving a cosmetic lip injection in a clinic setting.

Dermal fillers
  • Basic Information
    • Test Standards: GB (China National Standard), or Chinese Medical Device Industry Standards if GB is unavailable
    • Certification Body: NMPA
    • Testing Body: NMPA-registered laboratories, CNAS-accredited third-party laboratories equipped with GB/YY standards or Chinese guidelines
    • Main procedures
      • Product Safety Review (Technical Document)
      • QMS(GMP)-China GMP

🇹🇼 TAIWAN (TFDA)

  • Classification
ClassRiskExample
Class 1Low risk• Manual Surgical & Clinical Instruments: Surgical forceps, Mechanical stethoscopes
• Basic Patient Support & Mobility Aids: Elastic bandages, Manual hospital beds
• Non-invasive Examination Tools: Clinical glass thermometers, Surgical eye pads
Sterile surgical instruments laid out on blue surgical drapes ready for medical procedures in a clinical setting.

Surgical forceps
Class 2Moderate risk• Active Diagnostic & Monitoring Systems: Electrocardiograph/ECG machines, Electronic blood glucose monitors
• Endoscopic & Dental Instruments: Rigid/Flexible endoscopes, Dental handpieces
• Energy-based Aesthetic & Injectable Devices: High-frequency/RF skin care devices, Hyaluronic acid dermal fillers, Contact lenses
A close-up of a smiling woman using a facial skincare device indoors for healthy skin.

High-frequency/RF skin care devices
Class 3High risk• Implantable Cardiac & Circulatory Support Systems: Implantable pacemakers, Coronary/Vascular stents
• Life-Sustaining & Anaesthesia Equipment: Mechanical ventilators, Continuous anesthesia machines
• Permanent Surgical Implants: Artificial heart valves, Breast implants, Bone screws & plates
Close-up of advanced medical equipment in a sterile operating room setting.

Continuous anesthesia machine
  • Basic Information
    • Test Standards: Taiwan Standard, ISO, IEC
    • Certification Body: TFDA
    • Testing Body: TFDA-designated testing laboratory
    • Main procedures
      • Product safety review
      • QMS-Taiwan QMS

🇮🇳 INDIA (CDSCO)

  • Classification
ClassRiskExample
Class ALow risk• Manual Orthopedic & Mobility Aids: Manual wheelchairs, Walking aids, Crutches

• Non-invasive Examination Tools: Mechanical stethoscopes, Tongue depressors, Medical beds

• Consumables & Dressings: Elastic bandages, Surgical drapes, Non-sterile examination gloves
Steel crutches with wooden crossbar and handle leaned on plain white wall in hospital in daytime

Crutches
Class BLow to Moderate Risk• Basic Electronic Diagnostic Equipment: Digital thermometers, Electronic sphygmomanometers (Blood pressure monitors), ECG monitors

• Non-high-risk Invasive Devices: Hypodermic needles, Suction equipment, Disposable syringes

• Surgical Wear & Protective Gear: Sterile surgical gloves, Surgical gowns, Personal protective equipment
Close-up of sterile syringes aligned on a light blue surface, highlighting medical equipment.

Disposable syringes
Class CModerate to High Risk• Critical Life-Support & Therapy Systems: Infusion pumps, Mechanical ventilators, Dialysis machines

• Active Imaging & Diagnostic Systems: X-ray systems, MRI machines, Ultrasound imaging equipment

• Non-cardiovascular Fixation Implants: Bone fixation plates/screws, Orthopedic implants, Intraocular lenses
Black and white image of a modern MRI machine in a hospital room with overhead ceiling art.

MRI machines
Class DHigh Risk• Central Circulatory & Cardiac Implants: Implantable pacemakers, Heart valves, Drug-eluting stents

• Advanced Life-Sustaining Systems: Ventricular assist devices (VAD), Intra-aortic balloon pumps (IABP)
pacemaker, medical, implant, heart, rhythm, correction, device, cardiology, cardiostimulator, pacemaker, pacemaker, pacemaker, pacemaker, pacemaker

Implantable pacemakers
  • Basic Information
    • Test Standards: CDSCO Regulations, ISO, IEC
    • Certification Body: CDSCO Designated Organization
    • Testing Body: CDSCO Designated Organization
    • Main procedures
      • Product safety review
      • QMS-ISO 13485

🇧🇷 BRAZIL (ANVISA)

  • Classification
ClassRiskExample
Class ILow risk• Manual Surgical Instruments: Surgical scalpels, Surgical forceps & scissors
• Non-invasive Examination & Support Tools: Mechanical stethoscopes, Ophthalmoscopes, • Manual hospital beds
• Basic Consumables: Non-sterile bandages & Gauze, Surgical drapes
An empty hospital room equipped with two beds, monitoring equipment, and ambient lighting.

Manual hospital beds
Class IIModerate risk• Electronic Diagnostic & Monitoring Devices: Electronic sphygmomanometers, Digital thermometers, Hearing aids
• Sterile Surgical Wear & Disposables: Sterile surgical gloves, Disposable syringes, Blood storage bags
• Powered Home-use Skincare Devices: Low-power LED masks, Galvanic skin care tools
hand, hearing aid, hearing loss, listen, hearing aid, hearing aid, hearing aid, hearing aid, hearing aidhand, hearing aid, hearing loss, listen, hearing aid, hearing aid, hearing aid, hearing aid, hearing aid

Hearing aids
Class IIIHigh risk• Active Therapeutic & Imaging Equipment: Ultrasound imaging systems, X-ray machines, Magnetic Resonance Imaging/MRI
• Professional Aesthetic & Surgical Systems: High-intensity focused ultrasound/HIFU for clinical use, High-frequency/RF surgical units, Surgical lasers
• Absorbable Material & Injections: Hyaluronic acid dermal fillers, Absorbable surgical sutures, Contact lenses
Close-up of a cosmetic procedure using injectables on a woman's forehead in a clinic setting.

Hyaluronic acid dermal fillers
Class IVMaximum risk• Life-Sustaining & Central Nervous/Circulatory Implants: Implantable pacemakers, Coronary/Vascular stents, Heart valves
• Advanced Support & Anaesthesia Systems: Mechanical ventilators, Defibrillators, Anaesthesia workstations
• Long-term Neurological Implants: Neurological catheters, Spinal fixation systems
Hands using a defibrillator on a patient during an emergency CPR situation.

Defibrillators
  • Basic Information
    • Test Standards: RDC, ISO, IEC
    • Certification Body: ANVISA
    • Testing Body: Certification procedures performed by an INMETRO-accredited body (in the case of electronic products) / Recognition of test results from ILAC testing laboratories
    • Main procedures
      • Product safety review
      • QMS-ANVIS GMP or MDSAP

🇲🇽 MEXICO (SSA)

  • Classification
ClassRiskExample
Class ILow risk• Non-invasive Support Materials: Elastic bandages, Surgical caps & gowns, Cotton applicators

• Hospital Support Furniture: Crutches, Manual hospital beds, Examination tables

• Manual Surgical Instruments: Non-powered scalpel handles, Surgical forceps, Tongue depressors

• Basic Diagnostic Tools: Mechanical stethoscopes, Neurological hammers
Close-up of individually packaged sterile cotton swabs in a clear holder, ideal for medical use.

Cotton applicators
Class IIModerate risk• Powered Diagnostic & Therapeutic Devices: Blood pressure monitors, Hearing aids, Powered surgical instruments

• Short-term Invasive Consumables: Hypodermic syringes with needles, Contact lenses, Intravenous infusion sets

• Energy-based Aesthetic Devices: Medical LED masks, Microcurrent skin stimulators
Close-up view of modern dental instruments in a clinical setting, showcasing professional equipment.

Powered surgical instruments
Class IIIHigh risk• Central Circulatory & Neurological Implants: Cardiac pacemakers, Neurostimulators, Drug-eluting stents

• Deep Tissue Injectables & Materials: Hyaluronic acid dermal fillers, Absorbable surgical sutures, Orthopedic implants

• Life-Sustaining Equipment: Mechanical ventilators, Defibrillators
Healthcare professional conducting an EEG examination using a Brainscope device on a male patient.

Neurostimulators
  • Basic Information
    • Test Standards: NOM, IEC, ISO
    • Certification Body: COFEPRIS
    • Testing Body: COFEPRIS-designated testing laboratory
    • Main procedures
      • Product safety review
      • QMS-NOM-241-SSA1-2021 or MDSAP

⚫ Product Safety Review (Medical Device Testing)

It is a legal procedure to verify the safety and effectiveness of the device in accordance with each regulation.

You must apply for authorization/certification through product testing and inspection and technical document review.

◼️ Medical Device Testing

  1. Electrical safety(IEC 60601-1)
  2. EMC(IEC 60601-2)
  3. RF
  4. Essential performance(performance)
  5. Biocompatibility(ISO 10993-1)
  6. Transportation, Packaging Testing(ASRM-US)
  7. Usability Testing, Usability (IEC 62366-1)
  8. Software Validation (IEC 62304)
  9. Cybersecurity
    • IEC 624434-1: Standards related to general security
    • IEC/TR 60601-4-1: Medical device security
  10. Risk Management Report(ISO 14971) + FMEA
  11. Sterilization/Disinfection
  12. Label Manual
  13. Clinical Evaluatin Report (CER)

⚫ Technical Documents

Technical Documents?

Documents containing raw materials, structure, intended use, method of use, operating principle, precautions for use, test standards, etc., as data regarding the quality, such as safety and performance, of the product.

◼️ Medical Device Technical Documentation (Korean Standards)

1. Composition
• Medical device approval application + supporting documents (including clinical trial data)
• In the case of international standardization technical documents
◦ Medical Device Approval Application Details + Overview (STED, Summary Technical Documentation) + Attachments

2. Deadline based on the scope of attached materials
• Clinical trial data not required: 65-day processing period for applications for approval and technical documentation review materials excluding clinical trial data.
• Clinical trial data required: Application for approval, technical documentation including clinical trial data. Processing period for review materials: 80 days.

3. How to write
• Filling out the medical device approval application
• Preparation of attachments
◦ Comparison Table of Essentially Equivalent Items
◦ Information regarding the purpose of use
◦ Data on the operating principle
◦ Test standards, their basis, and actual measurement data as materials to verify product performance and safety
-Data on electrical and mechanical safety
-Biological safety data
-Safety data regarding radiation
-Data on electromagnetic safety
-Data regarding performance
-Data on physical and chemical properties
-Data regarding stability
• Data regarding origin or discovery and development history
• Data regarding clinical trials
• Data on usage status abroad, etc.

4. Application Documents
• Request for Review of Medical Device Technical Documents, etc.
◦ Data compared with already approved and certified products
◦ Data regarding the purpose of use
◦ Data on the operating principle
◦ Data regarding test standards, the basis for their establishment, and the actual measurement site as the following materials to verify the performance and safety of the product
• Data on electrical and mechanical safety
• Biological safety data
• Safety data regarding radiation
• Data on electromagnetic safety
• Data regarding performance
• Data on physical and chemical properties
• Data regarding stability
• Data regarding origin or discovery and development history
• Data regarding clinical trials
• Data on foreign usage status, etc.

Scroll to Top